Double-Wrap Cable Cleat.

The Identimark Double-Wrap Cable Cleat is a nylon-coated stainless steel strap that fixes, retains and secures cables in trefoil formation, and protects them from the electromechanical forces of a short-circuit fault. Made from halogen-free, nylon-coated 316L stainless steel and tested to IEC 61914:2015, classified Very Heavy. The 19 mm type is short-circuit tested to 177.4 kA peak.

Enquire about this product
Icons-3

Benefits

Tested for fault conditions

Tested to IEC 61914:2015 and classified Very Heavy, with the 19 mm type short-circuit tested to 177.4 kA peak.

Built for trefoil runs

The double-wrap design bundles three single-core cables tightly in trefoil formation.

Coated for cable protection

A halogen-free nylon coating protects the cable sheath, with no separate cushion strip needed.

Built for harsh environments

316L stainless steel suits coastal, corrosive and exposed sites.

Lengths to suit the run

Available in 16 mm and 19 mm widths, in lengths from 600 to 2,100 mm.

Fully tested system

Passes needle flame, lateral load and axial movement tests.

Vector

Options & Features

Vector (1)

Specifications

Tested for fault conditions

Tested to IEC 61914:2015 and classified Very Heavy, with the 19 mm type short-circuit tested to 177.4 kA peak.

Built for trefoil runs

The double-wrap design bundles three single-core cables tightly in trefoil formation.

Coated for cable protection

A halogen-free nylon coating protects the cable sheath, with no separate cushion strip needed.

Built for harsh environments

316L stainless steel suits coastal, corrosive and exposed sites.

Lengths to suit the run

Available in 16 mm and 19 mm widths, in lengths from 600 to 2,100 mm.

Fully tested system

Passes needle flame, lateral load and axial movement tests.

FAQs.

When should I use a strap cleat instead of a rigid cleat?

Strap cleats suit trefoil runs where a single strap around the bundle is easier to fit, or where cable sizes vary. Rigid cleats suit fixed sizes on ladder or channel. Talk to us about your installation.

What standards are these cleats tested to?

IEC 61914:2015, classified Very Heavy. It also passes needle flame, lateral load and axial movement tests.

What short-circuit current can they withstand?

The 19 mm type is tested to 177.4 kA peak. The rating you need depends on the prospective fault current, cable size and spacing.

Does it need a separate cushion strip?

No. The nylon coating protects the cable sheath on its own.

Explore similar products.

One strap. Fault rated.

Tell us your cable size, formation and outage date, and we'll match the cleat and plan the supply.